Ideal Boiler Error Codes

Ideal Boiler Error Codes

Ideal Error Codes
The Ideal range of powerful boilers are normally extremely reliable.

Occasionally some things can go wrong, that’s why we’ve created our handy at-a-glance table of Ideal error codes (below) as well as our guide to Common Ideal Boiler Problems & Repair Advice.

Should you need professional help with your broken boiler, then simply use one of our enquiry forms and we will connect you with the best heating engineers local to you.


Get Boiler Quotes

 
Get quotes to supply and fit a new boiler now

 


Ideal Boiler Error Codes

Listed below are some error codes that could appear on your Ideal boiler.

Fault Code System Behaviour
C0 BCC Activation Fault
C2 BCC Fault
F1 Low Water Pressure
F2 Flame Loss
F3 Fan Fault
F4 Flow Thermistor
F5 Return Thermistor
F6 Outside Sensor Failure
F7 Low Mains Voltage
F9 Unconfigured PCB
L1 Flow Temperature Overheat or No Water Flow
L2 Flame Loss
L5 5 Boiler Resets in 15 minutes
L6 False Flame Lockout

Ideal Boiler Error Descriptions

Listed below are some error Descriptions that you could be facing on your Ideal boiler.

Fault Description cause
Overheat Lockout Go to Frame 82 Overheat Lockout
Ignition Lockout Go to Frame 83 Ignition Lockout
Flame Loss Go to Frame 84 Flame Loss
Thermal Fuse Lockout Reset Boiler
Too Many Resets 5 Resets within 15 minutes Turn power off and on
Flame on before Gas Valve on Go to Frame 86 Flame On before Gas Valve On
Flow Thermistor Fault Go to Frame 87 Flow Thermistor Fault
outside sensor fault Go to Frame 87 Flow Thermistor Fault
Return Thermistor Fault Go to Frame 89 Return Thermistor Fault
Fan Fault Go to Frame 90 Fan Fault
PCB Replaced Incorrectly Ensure BCC fitted correctly Ensure correct BCC fitted
Low Mains Voltage Less than 160V to boiler Check voltage at boiler mains in Check if local generator 10V Contact Electricity Provider
Low Water Pressure Fill System to 1 Bar Bleed Radiators Refill System to 1 Bar
Flow/Return Reversed Check if Flow Thermistor correctly clipped to pipe Replace Flow Thermistor
No Water Flow Go to Frame 92 No Water Flow Fault
PCB Replaced Reset boiler by pressing r
No Connection to Primary PCB Unblock Pump
Pump Rotor Blocked If fault persists Go to Frame 93 No Connection to Primary PCB
NO CH BUT DHW OK Go to Frame 94 No CH but DHW OK
NO DHW BUT CH OK Go to Frame 95 No DHW but CH OK
BLANK DISPLAY Go to Frame 96 Blank Display
FLOW TEMPERATURE SETPOINT CANNOT BE INCREASED TO 80ºC Ensure Flow Temperature is not limited within Installer Mode (see Frame 37
PUMP RUNS DURING THE NIGHT Ensure System Frost Protection Temperature Setpoint is not set too high (see Frame 40)
Has PCB just been replaced? Reset Boiler
Are the Boiler and CH/DHW system filled with waterand are all Isolation Valves and Radiator Valves open? Fill and vent the system and open allIsolation Valves, then Reset the Boiler
Is the Flow/Return Differential across the boiler in excess of 30c Check the Flow and Return Thermistors(refer to Frames 87 & 89)
Check that the Pump is rotating freely. Replace the Pump, then Reset the Boiler
if the Boiler is Reset, does it Ignite for a short time and then extinguish check the Detection Electrode and associated Harness for continuity, visual condition and position (refer to Frame 59). Check if the Condensate Pipe is Blocked
is the gas pressure avaliable at the boiler > 18mBar Check Gas Supply and rectify fault
is 215Vdc avaliable at the gas valve during ignition Check wiring from Gas Valve to PCB and replace if necessary, otherwise replace the main PCB
unplug the gas valve is the resistance between the pins between 1Kw and 10KW Replace Gas Valve

Ideal Boiler Error Codes

Listed below are some error codes that could appear on your Ideal boiler.

Fault Code System Behaviour
0 The boiler is in standby mode awaiting either a central heating call or hot water demand
C The boiler has a call for central heating but the appliance has reached the desired temperature set on the boiler
D The boiler has a call for hot water but the appliance has reached the desired temperature set on the boiler
C The boiler is operating in central heating mode
d The boiler is operating in hot water mode
F The boiler is operating in frost mode

Get Boiler Quotes

 
Get quotes to supply and fit a new boiler now

 


Ideal Logic Max System / Logic Plus System Boiler Error Codes

Listed below are some error codes that could appear on your Ideal Logic Max or Logic Plus system boiler.

Fault Description System Behaviour
L1 Flow temperature overheat lockout or no water flow lockout
L2 Ignition lockout
LC Turn power off and on
L6 False flame lockout
F1 Low water pressure
F2 OR FN OR LN Flame loss
F3 Fan fault
L4 OR F4 Control / no flow thermistor fault
L5 OR F5 Return thermistor fault
F6 Outside sensor fault
F7 Low mains voltage Contact electricity provider
F9 OR L9 OR F8 OR L8 PCB unconfigured or fault
FU Diff greater than 50c check isolation valves are open
NO CH Contact an installer
NO HW Contact an installer
NO DISPLAY Contact an installer

Ideal Logic Max Plus Combi Boiler Error Codes

Listed below are some error codes that could appear on your Ideal Logic Max or Logic Pro Combi boiler.

Fault Description System Behaviour
Overheat lockout Bleed radiators refill system to 1.0 bar check radiator valve on boiler valves are open reset boiler if fault continues contacts an installer
Ignition lockout Check gas appliances work and restart boiler
To many restarts 5 starts within 15 minutes turn power on and off
Flame on before gas on False flame lockout
Water pressure With boiler off and system cold fill system to 1.0 bar and bleed radiators if fault continues contact an installer
Flame loss Flame loss
Fan fault Fan fault
Flow thermistor fault Flow thermistor error
Return thermistor fault Return thermistor error
Outside sensor fault Outside sensor error

Ideal Logic Max / Logic Plus Regular Boiler Error Codes

Listed below are some error codes that could appear on your Ideal logic max or logic plus regular gas boiler.

Fault Description System Behaviour
L1 Flow temperature overheat lockout or no water flow lockout
L2 Ignition lockout
LC 5 restarts within 15 minutes Turn power off and on
L6 False flame lockout
FA Flow return reversed
FD No water flow
F2 or Fn or Ln Flame loss
F3 Fan fault
L4 OR F4 Control / no flow thermistor fault
L5 OR F5 Return thermistor fault
F6 Outside sensor fault
F7 Low mains voltage Contact electricity provider
F9 OR L9 OR F8 OR L8 PCB unconfigured or fault
FU Diff greater than 50c check isolation valves are open
NO CH Contact an installer
NO HW Contact an installer
NO DISPLAY Contact an installer
Back to top

Ideal Vogue Boiler Error Codes

Listed below are some error codes that could appear on Ideal Boiler.

  • Vogue max combi
  • Vogue max system
  • Vogue combi gen2
  • Vogue system gen2
  • Fault Description System Behaviour
    Overheat lockout error Overheat lockout contact installer
    Ignition lockout Ignition lockout error contact installer
    Flame loss Flame loss error contact installer
    Thermal fuse lockout Flame loss contact installer
    To many resets 5 restarts within 15 minutes
    Flame on before gv on Flame on before gas valve is on
    Flow thermistor fault Flow thermistor error
    Outside sensor fault Outside sensor error contact installer
    Return thermistor fault Return thermistor error contact installer
    Fan fault Fan fault contact installer
    PCB error PCB Error contact installer
    Low mains voltage Less than 185v to boiler then check voltage at boiler mains in if mains voltage is okay pump needs replacing
    Low water pressure Low water pressure
    Flow return reversed check if the flow thermistor correctly clipped to pipe replace flow thermistor
    No water flow fault No water flow fault contact installer
    No water flow fault

    No water flow error contact installer
    PCB replaced Restart boiler by pressing restart
    Puno rotor blocked Unblock pump
    NO CH but DHW ok No ch but dhw okay contact installer
    No DHW but CH Ok No dhw but ch okay contact installer
    Flow temperature setpoint cannot be increased to 80 c Check flow and return thermistors securely clamped to pipes check flow and return thermistor